Cleared
Registry

Pools

Above-ground / inflatable / prefabricated pool

Prefab metal-wall, inflatable, or soft-side above-ground pool.

partialHB 803: excludedreviewed never

Who can pull the permit

  • NONENo contractor license
  • CPCCertified Commercial Pool/Spa Contractor
  • RPCertified Residential Pool/Spa Contractor
  • CGCCertified General Contractor
  • CBCCertified Building Contractor
  • CRCCertified Residential Contractor
  • OWNER-BUILDEROwner-occupied 1–2 family (FS 489.103(7))

Decision — first matching row wins

#WhenPermitTypeReason
1depth_in ≤ 24 AND hardwired is nonoA pool holding 24 inches of water or less does not meet the statutory definition of a 'swimming pool' under FS §515.25 (must exceed 24 in.) — it falls outside the barrier law, and a plug-in pump needs no electrical permit.
2depth_in ≤ 24yesElectrical Permit (pool itself stays unregulated)Water 24 inches deep or less stays outside FS §515.25's 'swimming pool' definition — no building/barrier permit — but a hardwired circuit to the pump is still permitted electrical work like any other dedicated circuit.
3otherwiseyesBuilding — Pool (FS 515 barrier) + Electrical if hardwiredOnce water depth exceeds 24 inches, FS §515.25 treats it exactly like an in-ground pool for barrier purposes — a compliant 4-ft barrier with self-closing/self-latching gates is mandatory, and most authorities require a permit for the installation and the barrier inspection even though the pool itself is prefabricated.

Inputs the rule needs

  • depth_inWater depth (in)required
  • hardwiredHardwired electrical (vs. plug-in pump)?

Documents (base)

  1. Owner authorization / signed permit application (owner or agent signature, notarized where the authority requires)
  2. Manufacturer spec sheet with water depth
  3. Barrier compliance sheet if over 24 in. (FS 515)
  4. Contractor registration current with the county (license, GL insurance, workers' comp or exemption on file)

Sources