Cleared
Registry

Commercial

Monument / wall / pylon sign (permanent)

Permanent freestanding or building-mounted sign.

partialHB 803: n/areviewed never

Who can pull the permit

  • CGCCertified General Contractor
  • CBCCertified Building Contractor
  • CRCCertified Residential Contractor
  • ECCertified Electrical Contractor
  • ERRegistered Electrical Contractor
  • SPEC-ALUMINUMAluminum / Screen Enclosure (county specialty)

Decision — first matching row wins

#WhenPermitTypeReason
1otherwiseyesSign Permit (zoning allowance + structural; electrical if lit)Permanent signs need a sign permit against the zoning code's size/height/number allowance, structural/wind for freestanding signs, and an electrical permit if illuminated. Both counties and every city regulate signage separately.

Inputs the rule needs

  • illuminatedIlluminated?
  • freestandingFreestanding (monument/pylon)?

Documents (base)

  1. Owner authorization / signed permit application (owner or agent signature, notarized where the authority requires)
  2. Sign drawings with dimensions & engineering
  3. Zoning sign-allowance calculation
  4. Electrical if illuminated
  5. Site plan / survey showing property lines, setbacks, easements, septic and the proposed work
  6. Contractor registration current with the county (license, GL insurance, workers' comp or exemption on file)

Sources