Registry
Roofing & Envelope
Stucco / siding repair or replacement
Patch stucco, re-stucco, replace siding.
partialHB 803: eligiblereviewed never
Who can pull the permit
- CGCCertified General Contractor
- CBCCertified Building Contractor
- CRCCertified Residential Contractor
- NONENo contractor license
- OWNER-BUILDEROwner-occupied 1–2 family (FS 489.103(7))
Decision — first matching row wins
| # | When | Permit | Type | Reason |
|---|---|---|---|---|
| 1 | scope = "replace" | yes | Building — Exterior Finish Replacement | Full envelope replacement (WRB, lath, siding) is permitted work. |
| 2 | otherwise | no | — | Ordinary non-structural repairs of exterior finish are exempt under FBC §105.2; Collier's Ord. 2009-59 additionally exempts stucco applied directly onto CMU and awning/gutter work on single-family residences. |
Inputs the rule needs
- scopeScoperequired
Documents (base)
- Owner authorization / signed permit application (owner or agent signature, notarized where the authority requires)
- Contractor registration current with the county (license, GL insurance, workers' comp or exemption on file)
Sources
- Florida Building Code, Building §105.1 (Permits required) & §105.2 (Work exempt from permit)
- Collier Ordinance 2009-59 — local FBC §105.2.4 minor-repair exemptions for single-family (≤$1,500 per trade repair; roof repair ≤$1,500 or ≤2 squares; finish work; screening an existing covered patio; stucco on CMU; awnings/gutters; door replacement not enlarging the opening) checked 2026-08-18